What was found
MAIN CABIN AFT WET AREA FLOORBOARD DELAMINATION. GROUNDED - YES. FABRICATED NEW FLOORBOARD IAW SRM 53-00-50-2R-0 AND DWG 147A5810-123, REV-.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN AFT WET AREA FLOORBOARD DELAMINATION. GROUNDED - YES. FABRICATED NEW FLOORBOARD IAW SRM 53-00-50-2R-0 AND DWG 147A5810-123, REV-.