What was found
FWD PIT AFT BULKHEAD STA 500L LOWER SUPPORT IS CORRODED. GROUNDED - YES. REMOVED AND REPLACED LOWER BLEND SUPPORT ANGLE IAW SRM 51-40-02-0G-0 STEP 7.A. 1-4 W= 2.0" O= .080 R= .050 L= 3" D= .030.