What was found
AFT WET AREA FLOOR SUPPORT HAS CORROSION BETWEEN STA 907-927 LBL 20. GROUNDED - YES. REPAIRED AFT WET AREA FLOOR SUPPORT BETWEEN STA 907-927 LBL 20 IAW EA 800-53EA-30625 W= 1.0" O= .076" R= .055" L= 1.0" D= .021.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT WET AREA FLOOR SUPPORT HAS CORROSION BETWEEN STA 907-927 LBL 20. GROUNDED - YES. REPAIRED AFT WET AREA FLOOR SUPPORT BETWEEN STA 907-927 LBL 20 IAW EA 800-53EA-30625 W= 1.0" O= .076" R= .055" L= 1.0" D= .021.