What was found
FWD CARGO AFT BULKHEAD LOWER SUPPORT CORRODED STA 500I. GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 53-30-08-1A-1, REMOVED AND REPLACED IAW SRM 51-40-02-0G-0 W: 1" O: 0.071" R: 0.022" L: 2" D: 0.049".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO AFT BULKHEAD LOWER SUPPORT CORRODED STA 500I. GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 53-30-08-1A-1, REMOVED AND REPLACED IAW SRM 51-40-02-0G-0 W: 1" O: 0.071" R: 0.022" L: 2" D: 0.049".