What was found
AFT WET AREA FLOOR SUPPORT BS 967 - 986, LBL 20 CORRODED. GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51-1A-1. REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 51-40-02-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.