As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FRONT HALF OF AIRCRAFT EMERGENCY LIGHTS INOP. GROUNDED - YES. REMOVED AND REPLACED EMERGENCY LIGHTS BATTERY POWER SUPPLY PER AMM 33-51-03. OPS CHECK GOOD. REMOVED AND REPLACED OVERWING EMERGENCY EVAC BATTERY POWER SUPPLY PER AMM 33-51-06. OPS CHECK GOOD. OK FOR SERVICE.