What was found
SEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE AFT OF ROW 27. RECONNECTED WIRE HARNESS IN TWO PLACES AFT OF ROW 27 AND LIGHTS OPERATED NORMALLY. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE AFT OF ROW 27. RECONNECTED WIRE HARNESS IN TWO PLACES AFT OF ROW 27 AND LIGHTS OPERATED NORMALLY. (M)