What was found
SEA - DURING MAINTENANCE CHECK, THE AFT QUARTER OF EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. FOUND WIRE PULLED OUT OF SPLICE AT TRACK, RECRIMPED WIRING AND LIGHTS OPERATED NORMALLY. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SEA - DURING MAINTENANCE CHECK, THE AFT QUARTER OF EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. FOUND WIRE PULLED OUT OF SPLICE AT TRACK, RECRIMPED WIRING AND LIGHTS OPERATED NORMALLY. (W)