What was found
PAE - DURING 15K CHECK, CORROSION WAS FOUND ON FRAME AT Y1271, X PLUS 19 TO X-19. CORROSION REMOVAL FROM X PLUS 19 TO X-14 WAS WITHIN LIMITS, X-14 TO X-19 WAS OUT OF LIMITS. REMOVED DAMAGED AREA AND INSTALLED NEW PIECES IAW DC-9 SRM 51-10-03, 51-20-00, 51-30-02 AND 53-03. (M)