What was found
PHX - DURING SCHEDULED D-CHECK, STRINGER 20L AT STATION 907 WAS FOUND TO BE BROKEN. REPAIRED PER SRM 51-30-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PHX - DURING SCHEDULED D-CHECK, STRINGER 20L AT STATION 907 WAS FOUND TO BE BROKEN. REPAIRED PER SRM 51-30-2. (M)