What was found
PHX - DURING SCHEDULED D-CHECK, THE FRAME AT STATION 847 STRINGER 24R TO 25R WAS FOUND CORRODED. REPAIRED PER SB 737-53-1096. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PHX - DURING SCHEDULED D-CHECK, THE FRAME AT STATION 847 STRINGER 24R TO 25R WAS FOUND CORRODED. REPAIRED PER SB 737-53-1096. (M)