What was found
PHX - DURING SI CHECK, FOUND MAIN FLOORBEAM T-CAP AT BS 986, LBL 34 CORRODED AROUND SCREW HOLES. REPAIRED PER SRM 53-60-51, FIG 203. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PHX - DURING SI CHECK, FOUND MAIN FLOORBEAM T-CAP AT BS 986, LBL 34 CORRODED AROUND SCREW HOLES. REPAIRED PER SRM 53-60-51, FIG 203. (M)