What was found
PHX - DURING 30K CHECK, THE FORWARD CARGO COMPARTMENT DOOR CUTOUT, LOWER SILL WAS FOUND CORRODED AROUND RIVET HOLES FROM STATION 370-427 ABOVE LONGERON 28R. REPAIRED PER SRM 53-05, FIG 44. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PHX - DURING 30K CHECK, THE FORWARD CARGO COMPARTMENT DOOR CUTOUT, LOWER SILL WAS FOUND CORRODED AROUND RIVET HOLES FROM STATION 370-427 ABOVE LONGERON 28R. REPAIRED PER SRM 53-05, FIG 44. (M)