What was found
DURING OVERNIGHT SERVICE, FOD´S WERE DETECTED ON 15 BLADES OF LT ENGINE. BOROSCOPE INSPECTION WAS PERFORMED ON C6 AND C7 COMPRESSOR STAGE IAW MM 72-00-00 AND NO DAMAGE WAS DETECTED. ON FAN STAGE, 3 BLADES WERE DETECTED WITH DAMAGES AND C1 FAN STAGE WAS REPLACED IAW MM 72-33-02, TEST CORRECT.