What was found
DURING OVERNIGHT SERVICE WAS DETECTED RT ENGINE WITH HIGH EGT INDICATION. EGT INDICATION WAS CHECKED IAW MM 77-21-00 AND THERMOCOUPLE NR 4 WAS DETECTED WITH DAMAGE, IT WAS REPLACED IAW MM 77-21-03. PT2 AND PT7 WERE CHECKED AND NO LEAKS WERE DETECTED, TRIMMING WAS PERFORMED IAW MM 71-00-00, BUT DURING TAKE OFF POWER TEST, THE MAXIMUM TAKE OFF 2.069 (2.06 OF EPR) WAS NOT REACHED, IT ONLY WAS REACHED 2.02. RT ENGINE WAS REPLACED IAW MM 71-00-00 AND TESTED IAW MM 77-00-01, ALL CORRECT.