What was found
AIRCRAFT RETURNED TO PLATFORM AS A CONSEQUENCE OF DURING TAXING, RIGHT HYDRAULIC SYSTEM WAS FAILED. DURING REVISION, RIGHT HYDRAULIC PUMP CONTINUED INDICATING PRESSURE WHEN IT WAS SHUTOFF AND HYDRAULIC POWER TRANSFER UNIT (PTU) WAS DETECTED WITH FAIL. THE PTU WAS REPLACED IAW MM 29-10-08, TESTED CORRECT.