As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AIRCRAFT RETURNED TO PLATFORM, DURING THE LT ENGINE START, THE FIRE EXTINGUISHER AGENT 2 LOW LIGHT TURNED ON. THE FIRE EXTINGUISHER POSITION 2 WAS REPLACED IAW MM 26-20-01; LT AUGMENTING VALVE WAS ADJUSTED IAW MM 36-10-01; THE CLAMS OF AUGMENTING VALVE AND REGULATOR VALVE WERE REPLACED IAW MM 20-10-11 AND LEAKS CHECK WAS PERFORMED IAW MM 21-10-00, MM 30-10-00 AND MM 36-10-00, TESTED CORRECT.