What was found
AIRCRAFT REJECTED TAKEOFF AT LESS THAN 60 KNOTS, CONFIGURATION WARNING APPEARED. MAINTENANCE PERSONNEL PERFORMED PSEU TEST AND OBTAINED THE FAILURE CODES 31-55006 (STAB TRIM GND) 31-5507 (STAB TRIM NOT GND) AND 31-55008 (T.O.WARN INHIBIT). PERFORMED THE REVIEW AND RESET OF SWITCHES P6-3, C-18 (LANDING GEAR TAKE OFF WARNING CUOFF) AND P6-3, D-18 (LANDING GEAR AURAL WARNING) IAW FIM31-51 PROCEDURE TASK 821; ADDITIONALLY, WARNING TAKE OFF ALARM TEST WAS PERFORMED IAW FIM 31-51 PROCEDURE TASK 801, ALL CORRECT.