What was found
CAPTAIN REPORTED THAT DURING TAKEOFF RUN THE LT ENGINE EGTS INDICATION EXCEEDED RED DIAL; CAPTAIN REDUCED THE THRUST RECOVERING NORMAL INDICATIONS. AT CDG, MAINTENANCE DETERMINED THAT EXCEED WAS WITHIN LIMITS IAW MM 71-00-00-613, REQUIRING BOROSCOPIC INSPECTION WITHIN 10 CYCLES. LATER, FIM PROCEDURE 73-22 TASK 819 WAS PERFORMED TO THE LT ENGINE AND OVER TEMPERATURE BOROSCOPIC INSPECTION WAS PERFORMED IAW MM 71-00-00-200-814-G00 AND 72-00-00-290-812G00, NO DAMAGES WERE FOUND. LT ENGINE WAS WASHED IAW MM 72-00-00-100-807-G00, AND THE POWER CHECK NR 7 WAS PERFORMED IAW MM 71-00-00-700-807-G00, ALL CORRECT.