What was found
DURING TRANSIT CHECK WAS DETECTED GEAR DOOR OPEN LIGHT TURNED ON. TECH VERIFIED TARGET SENSORS AND PERFORMED AUTO TEST TO THE PROXIMITY SWITCH, BUT LIGHT CONTINUED; SO PROXIMITY SWITCH WAS REPLACED IAW MM 36-60-04, REMAINING SAME CONDITION. AC WAS SENT TO THE HANGAR AND MAIN LANDING GEAR DOORS TARGET SENSOR WAS ADJUSTED IAW MM 32-60-05, TESTED CORRECT.