What was found
ACFT REJECTED TAKEOFF AT 80 KNOTS AND GROSS WEIGHT OF 67 870 KG DUE TO THRUST ASYMMETRY OF 97 PERCENT N2 ON LT ENGINE AND 103 PERCENT N2 ON RT ENGINE AND LT THRUST LEVEL CUT BACK AUTOMATICALLY AFTER TRYING TO EQUAL POWER. MX PERFORMED BITE IN EEC IAW MM 73-21-00, NO FAILURE CODE WAS SHOWN AND ENGINE POWER RUN UP IAW MM 71-00-00, TEST 5 POWER ASSURANCE CHECK, TESTED CORRECT. THE HIGH ENERGY STOP INSP WAS PERFORMED IAW MM 05-51-07, NO DAMAGES WERE FOUND.