What was found
DURING TRANSIT CHECK, DETECTED A FUEL LEAK IN RT ENGINE WITH 94 DROPS PER MINUTE. MX DETECTED ACTUATOR DRAIN LINE VSVS WITHIN OPERATION LIMITS IAW MM 75-31-00. MX REPLACED THE ACTUATOR VSVS IAW MM 71-00-00 PAGE 501, TESTED CORRECT.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING TRANSIT CHECK, DETECTED A FUEL LEAK IN RT ENGINE WITH 94 DROPS PER MINUTE. MX DETECTED ACTUATOR DRAIN LINE VSVS WITHIN OPERATION LIMITS IAW MM 75-31-00. MX REPLACED THE ACTUATOR VSVS IAW MM 71-00-00 PAGE 501, TESTED CORRECT.