What was found
DURING OVERNIGHT CHECK, MX PERSONNEL DETECTED A SCRATCH IN THE SKIN FUSELAGE OF THE 1.5" LONG, 0.084" WIDE BETWEEN LONGERONS 22 AND 23, AT STATION 848. FOUND WITHIN LIMITS IAW SRM 51-00-01 ALLOWABLE DAMAGE 1, PARAGRAPH 4B (2) (A) FIGURE 103 DETAILS P AND Q. NDT INSPECTION PERFORMED, NO CRACKS FOUND IAW NDTM PART 4, 51-00-00 FIG 2 AND NDTM PART 6, 51-00-00 FIG 23, ALL CORRECT.