What was found
DURING TRANSIT CHECK, IT WAS DETECTED A LIGHTNING STRIKE IN RT WINGLET T/E AND FIN TIP FITTING TR/E OF VERTICAL STABILIZER. MX PERSONNEL PERFORMED A LIGHTNING STRIKE INSPECTION IAW MM 05-51-19 DETECTING BURNED MARKS IN RT WINGLET T/E AND FIN TIP FITTING T/E OF VERTICAL STABILIZER, DAMAGES FOUND WITHIN LIMITS IAW SRM 55-30-30 ALLOWED DAMAGE 1, PARA B (5) (A) FIG 104. THE NON ROUTINE CARDS A0208436 AND A0208437 WERE ISSUED FOR REPAIR DAMAGES AND THE BURNED IN RT WINGLET T/E AND FIN TIP FITTING T/E OF VERTICAL STABILIZER WERE REWORKED IAW SRM 55-30-30 ALLOWED DAMAGE 1 PARA B 5, A, FIG 104; ALL CORRECT.