What was found
DURING OVERNIGHT CHECK, MX PERSONNEL ATTENDED THE NRC A0732762 TO CORRECT FUEL LEAK IN RT ENGINE OF 40 DROPS IAW MINUTE THROUGH THE FUEL PUMP PAD DRAIN DURING IDLE POWER OPERATION. RT ENGINE FUEL PUMP WAS REPLACED IAW AMM 73-11-01, TESTED CORRECT.