What was found
DURING 500 HOURS CHECK, DETECTED AN OIL LEAK ON BOTH ENGS. MX PERSONNEL PERFORMED ENG LEAKING INSPECTION IAW AMM 73-21-00 DETECTING OIL LEAK IN THE LUBRICATION UNIT OF BOTH ENGS. THE LT LUBRICATION UNIT WAS REPLACED & THE RT LUBRICATION UNIT SEAL WAS REPLACED IAW AMM 79-21-01 & BOTH ENGS WERE RUN IAW AMM 71-00-00, TEST 3A, ALL CORRECT.