As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING RT ENGINE START, A FUEL LEAK WAS DETECTED & THE RT ENGINE CONTROL LIGHT TURNED ON WITH INDICATION OF EGT LOW. AIRCRAFT RETURNED TO PLATFORM. PERFORMED REVISION, DETECTING FUEL LEAK IN THE TRANSIENT BLEED VALVE DRAIN PORT. THE RT ENGINE WAS MOTORING, AFTER IT WAS STARTED & ENGINE OPS TEST WAS PERFORMED IAW AMM 71-00-00, NO CONFIRMING FUEL LEAK & THE CONTROL LIGHT TURNED OFF, ALL CORRECT.