What was found
AIRCRAFT REJECTED TAKE OFF AT 60 KNOTS DUE TO THE ENTRY DOOR LIGHT TURNED ON. THE FLIGHT CREW PERFORMED THE QRH 1.8 PROCEDURE, NO CONFIRMING THE FAILURE & INITIATING AGAIN SEQUENCE OF TAKEOFF. AS PRECAUTIONARY ACTION, PERFORMED BITE TO ENTRY DOOR FLIGHT LOOK SWITCH IAW FIM 52-10 TASK 801 PROCEDURE, NO FOUND FAILURE & THE HIGH ENERGY STOP INSPECTION WAS PERFORMED IAW MM 05-51-07, NO DAMAGES WERE FOUND.