What was found
CAPTAIN REPORTED THAT DURING CLIMB, THE LT ENG VIBRATION REACHED 4.2 UNITS. PERFORMED FIM 71-05 TASK 808 PROCEDURE, NO DAMAGES WERE FOUND, TESTED CORRECT. AS PRECAUTIONARY ACTION, REPLACED THE VIBRATION MONITOR IAW AMM 77-31-03-401 & TRIM BALANCE WAS PERFORMED IAW AMM 71-00-00 TASK 71-00-00-750-803, TESTED CORRECT.