What was found
CAPTAIN REPORTED LE FLAP TRANSIT LIGHT ON. MAINTENANCE PERFORMED AN INSPECTION DETECTING A CRACK OF 1 X 0.250 INCHES IN CUT OUT FIXED LE INBOARD AUX TRACK SLAT 1 STATION 453 AND A CRACK OF 1 X 3 INCHES IN CUT OUT LE INBOARD MAIN TRACK SLAT 1 STATION 409. THEREFORE FIXED EDGE OF LEFT WING WAS REMOVED BETWEEN STATIONS S.S.384.285. AND S.S.519.04, AND WAS REPAIRED IAW SRM 57-41-01. ULTRASONIC INSPECTION WAS ACCOMPLISHED ON REPAIR AND SURROUNDING AREA IAW NDTM PART 4 51-00-02, ALL CORRECT.