What was found
CAPTAIN REPORTED THAT DURING CRUISE, THE FUEL QUANTITY INDICATION WAS WRONG, FUEL QUANTITY WAS VERIFIED USING FUEL DIPSTICK. OPS TESTED FOR THE SYSTEM FUEL QUANTITY INDICATOR PERFORMED IAW AMM 28-24-00, FUEL TRANSFER WHEN NOT COMMANDED WAS PERFORMED IAW FIM 28-22 TASK 849, DETECTING THE CENTRAL TANK FUEL LEFT OVERRIDE PUMP WITH FAULT, THEREFORE PUMP WAS REPLACED IAW AMM 28-22-06, ALL TESTED CORRECT.