What was found
DURING OVERNIGHT CHECK OF AUGUST 09, 2018, A FUEL LEAKAGE WAS DETECTED IN RIGHT ENGINE. MAINTENANCE PERSONNEL PERFORMED A REVISION DETECTING FUEL PUMP DRAIN OF 80 DROPS PER MINUTE BEING OUT OF LIMITS IAW AMM 71-71-00, THE POWER PLANT TEST 3A WAS PERFORMED IAW AMM 71-00-00, CONFIRMING FAILURE; SO RIGHT FUEL PUMP WAS REPLACED IAW AMM 73-11-00, TESTED CORRECT.