What was found
DURING OVERNIGHT CHECK AT MEX STATION, DUE TO BORESCOPE INSPECTION AT LEFT ENGINE. MAINTENANCE PERSONNEL PERFORMED LEFT ENGINE BORESCOPE INSPECTION, DETECTING OIL LEAK BY IDG DRAIN WITH 45 DROPS PER MINUTES; SO THE IDG SEALOL SEAL WAS REPLACED IAW AMM 72-60-00 AND OPERATIONAL TEST WAS PERFORMED IAW AMM 71-00-00, TESTED CORRECT.