What was found
24.06.2021 13:44 A GOUGE ON RH HORIZONTAL STABILIZER LEADING EDGE. DURING TRANSIT CHECK, IT WAS DETECTED A DAMAGE ON RIGHT HORIZONTAL STABILIZER LEADING EDGE. MAINTENANCE PERSONNEL PERFORMED REVISION, DETECTING A GOUGE OF 1.00" LENGTH, 0.625" WIDTH AND 0.104" DEPTH ON RIGHT HORIZONTAL STABILIZER LEADING EDGE AT STA 184.98; GOUGE WAS EVALUATED AND FOUND OUT OF LIMITS IAW SRM 55-10-01-1A-1, PARAGRAPH 4.A, TABLE 101; ET, DVI AND ETHF INSPECTIONS WERE PERFORMED IAW B737 NDTM PART 6 51-00-00, PROCEDURE 23; A GOUGE WAS REWORKED IAW SRM 55-10-01, PARAGRAPH 5.C.(6)(7); RH HORIZONTAL STABILIZER LEADING EDGE WAS REMOVED IAW AMM 24741-21-000-801; A DAMAGE WAS REMOVED IAW SRM 55-10-01, REPAIR 1, PARAGRAPH 4.A; HFEC INSPECTION ON CUT-OUT AREA WAS PERFORMED IAW B737 NDTM PART 6 51-00-00 PROCEDURE 23; RH HORIZONTAL STABILIZER WAS REPAIRED IAW SRM 55-10-01, REPAIR 1; RH HORIZONTAL STABILIZER LEADING EDGE WAS INSTALLED IAW AMM 24-41-21-400-801, ALL CORRECT.