What was found
DURING C-CHECK INSPECTION IN BNA, FOUND CORROSION ON THE CENTER OMEGA BEAM BETWEEN FRAME STATION 5518-5533. MX REPAIRED THE CORRODED OMEGA BEAM IAW ASA EO120-53-0173. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK INSPECTION IN BNA, FOUND CORROSION ON THE CENTER OMEGA BEAM BETWEEN FRAME STATION 5518-5533. MX REPAIRED THE CORRODED OMEGA BEAM IAW ASA EO120-53-0173. (M)