What was found
DURING A C-CHECK IN MCN, THE LOWER METAL TRIM PANEL NUT PLATE ANGLE AT THE SERVICE DOOR ENTRANCE WAS FOUND TO BE CORRODED BEYOND LIMITS. MAINTENANCE IS REMOVING THE LOWER METAL PANEL NUT PLATE ANGLE AT THE SERVICE DOOR ENTRANCE IAW SRM 51-00. (M)