What was found
FLT 4460 - DURING A GROUND INSPECTION IN DFW, THE EMERGENCY LIGHTING AT ROWS 9 TO 14 WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE AFT EMERGENCY FLOOR LIGHT CONNECTOR, FLEX LAMP P/N 362624, AT ROW 10, CABLE ASSY AT ROWS 9-14, AND THE FLOOR TRACK COVER. OPS CHECKS GOOD. AIRCRAFT OK FOR SERVICE. (M)