What was found
DURING A C-CHECK, THE IB AND OB CLIPS AT FS 484, RBL 27 AND RBL 36 WERE FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE IS REMOVING AND REPLACING THE IB CLIP AT FS 484, RBL 27 AND REPAIRING THE OB CLIP AT FS 484, RBL 36 IAW EO600-53-0098.