What was found
DURING A C-CHECK, THE FLOORBEAM AT FS 559+80, BETWEEN RBL 9.00 AND RBL 27.00, WAS FOUND TO BE CORRODED BEYOND LIMITS. MAINTENANCE REMOVED AND REPLACED THE FLOORBEAM AT FS 559+80, BETWEEN RBL 9.0 AND RBL 27.00, IAW SRM. (K)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A C-CHECK, THE FLOORBEAM AT FS 559+80, BETWEEN RBL 9.00 AND RBL 27.00, WAS FOUND TO BE CORRODED BEYOND LIMITS. MAINTENANCE REMOVED AND REPLACED THE FLOORBEAM AT FS 559+80, BETWEEN RBL 9.0 AND RBL 27.00, IAW SRM. (K)