DURING A C-CHECK IN YUL, THE FLOORBEAM AT FRME 40 LT/RT WAS FOUND TO BE CORRODED BEYOND LIMITS. MAINTENANCE REMOVED AND REPLACED THE FLOORBEAM AT FRAME 40 LEFT/RIGHT IAW SRM 51-25-01. (M)