What was found
DURING A C-CHECK IN MCN, THE RIGHT SIDE PRESSURE FLOOR SILL AT FS 484 WAS FOUND TO BE CORRODED BEYOND LIMITS. MAINTENANCE IS SUBMITTING A DAMAGE REPORT TO BOMBARDIER FOR ISSUANCE OF AN REO TO DETERMINE THE APPROPRIATE CORRECTIVE ACTION. MAINTENANCE REPAIRED THE RT SIDE PRESSURE FLOOR SILL AT FS 484 IN ACCORDANCE WITH ASA EO 600-53-0319 CLOSED (M)