What was found
DURING A C--CHECK IN YUL, THE FLOORBEAM AT FS 36 WAS FOUND TO BE CORRODED BEYOND LIMITS. MAINTENANCE REMOVED AND REPLACED THE FLOORBEAM AT FS 36, IAW ASA EO 72-53-0170. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A C--CHECK IN YUL, THE FLOORBEAM AT FS 36 WAS FOUND TO BE CORRODED BEYOND LIMITS. MAINTENANCE REMOVED AND REPLACED THE FLOORBEAM AT FS 36, IAW ASA EO 72-53-0170. (M)