What was found
C/W STEPS 1, 4, 5, 6, AND 7 OF REO 601-R52-11-1571. NDT REQUIRED. PERFORMED EDDY CURRENT INSP ON PAX DOOR AFT SIDE SKIN BETWEN STEPS 2 AND 3 (CUTOUT) AT CORNER OF BOTTOM STEP. NO REJECTABLE INDICATIONS FOUND AT THE TIME, REPORT ATTACHED IAW STEP 2 OF REO 601R-52-11-1571 AND NDTM 51-20-06. RESTORE FINISH IS REQUIRED. C/W STEPS 3-9 OF REO 601R-52-11-1571, STEPS 10 AND 11 PAINT REQUIRED. EDGE SEALED AND PAINTED REPAIR IAW REO 601R-52-11-1571 STEPS 10 AND 11. C/W STEPS 12-15 OF REO 601R-52-11-1571. C/W ASA EC/TC REO 601R-52-11-1571.