What was found
AT FS 718.0 BETWEEN STRINGERS 11L AND 13L PREVIOUSLY REPAIRED ATTACH ANGLES ARE CRACKED IN RADIUS (2 EA). REMOVED PREVIOUS REPAIRS FROM FS 718.0 BETWEEN STRINGERS 11L AND 12L IAW CRJ 200 SRM 51-42-06 AND 51-42-21. CUTLINE AS PER REO 601R-53-61-193 AND CRJ 200 NDTM 51-20-08. NO INDICATIONS NOTED AT THIS TIME. REPAIRED FS 718.00 BETWEEN STRINGERS 11L AND 12L IAW STEPS 2 THROUGH 6 OF BOMBARDIER REO 601R-53-61-193. STEP 1 OF BOMBARDIER REO 601R-53-61-193 TRIM OUT OF FLANGE WAS PREVIOUSLY COMPLIED WITH. ALL WORK WAS COMPLIED WITH IAW ASA EO 600-53-0067 REV A. SUPPLEMENTAL-SDR CLOSED 11/13/2008.