What was found
RT FUSELAGE EXTERIOR SKIN 3 INCHES FWD OF FS 559+96 AT STR 23R HAS MINOR SURFACE CORROSION. REMOVED 7 RIVETS, THEN REMOVED CORROSION AND INSTALLED 7 NEW SERVICEABLE RIVETS IAW CRJ 200 SRM 51-21-06, 53-51-31, AND 51-42-06 AT RT FUSELAGE EXTERIOR SKIN 3 INCHES FWD OF FS 559+96 & AT STR 23R. AREA NEEDS PAINT. TOUCHED UP REPAIR AREA IAW CRJ SRM 51-25-16. MAX MATERIAL REMOVED .003. SUPPLEMENTAL-SDR CLOSED 11/17/2008.