As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RT SIDE PRESSURE FLOOR SILL PLATE HAS CORROSION FROM FS 409+128 TO FS 559, RBL 36 TO RBL 44. REMOVED CORROSION ON R PRESSURE FLOOR SILL PLATE. REQUIRES REO 601R-53-41-666, STEPS 2.2 C THRU F COMPLIANCE. PERFORMED EDDY CURRENT INSPECTION ON BLENDED AREAS. NO INDICATIONS FOUND AT THIS TIME.