What was found
LT FLOOR SUPPORT STRUCTURE IS CRACKED AT FS 621, LBL 40, WL 73. REPAIRED CRACKED LT SIDE FLOOR SUPPORT STRUCTURE AT FS 621, LBL 40, WL 73 IAW REO 601R-53-61-117 REV C. COMPLIED WITH ECTC REO 601R-53-61-117.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT FLOOR SUPPORT STRUCTURE IS CRACKED AT FS 621, LBL 40, WL 73. REPAIRED CRACKED LT SIDE FLOOR SUPPORT STRUCTURE AT FS 621, LBL 40, WL 73 IAW REO 601R-53-61-117 REV C. COMPLIED WITH ECTC REO 601R-53-61-117.