What was found
LT WING MULTI-FUNCTION SPOILER CLOSEOUT PANEL CRACKED AT INBD AFT CORNER. R & R RT MFS CLOSE OUT PANEL IAW SRM 51-42-06, 51-42-13, 51-42-21. REFER TO M-234 FORM FOR WORK ACCOMPLISHED. REMOVED MFS CLOSEOUT PANEL PER SRM 51-42-00. REMOVED RT O/B FLAP VANE PER CMM 57-53-02. FITTED & DRILLED RT MULTI FUNCTION SPOILER CLOSEOUT PANEL PER SB670BA-57-010 & SRM 51-40-11. COUNTER SUNK & FINAL SIZED MULTI-FUNCTION SPOILER MOUNTING HOLES & DRILLED P-SEAL FASTENER HOLES PER SB670BA-57-010. OK TO INSTALL. INSTALLED IAW SRM 51-42-21 & 51-42-06 REFERENCE FASTENERS SB670BA-57-010. RESTORED A023 FINISH ON RT MFS CLOSE OUT PANEL IAW SRM 51-21-06. INSTALLATION OF RT FLAP VANE PERFORMER ICW EO 700-57-0062.