What was found
OPS 193 CONTINUED FROM JOB NR 8733515 OP NR 173. FS 409.0+128 VERTICAL POST BL 0 HAS INDICATION NOTED APPROX 3 INCH IN LENGTH 90 PERCENT FULL SCREEN HEIGHT RT SIDE WL 69.0 FLANGE, FAILED NDT INSP. INSTALLED NEW SERVICEABLE REINFORCING ANGLE ON POST BL 0 AT WL 69.0 IAW REO 601R-53-41-844 AND SRM 51-42-06 AND 51-42-22. CABIN AIR SUPPLY DUCT REQUIRES RECONNECT AT FS 409+128 TO "Y" DUCT. CONNECTED CABIN AIR SUPPLY DUCT TO "Y" DUCT AT FS 409+128. INSTALLED AND TIGHTENED BAND CLAMP. COMPLIED WITH EC/TC REO 601R-53-41-844 AND MET ALL THE REQUIREMENTS OF REO 601R-53-41-844. RII COMPLIED WITH.