What was found
LT AND RT FS 559 BULKHEAD WEB AND CAP ANGLE HAVE INDICATIONS AT CAP ANGLES LBL RBL 18 APPROX .3" IN LENGTH 90% FSH AND RT WEB AT WL 58.10 APPROX .2" IN LENGTH 60% FSH, WL 54.10 APPROX .5" IN LENGTH 80% FSH AND WL 59.10 APPROX 1.0" IN LENGTH 100% FSH. ALL THESE AREAS FAILED NDT INSPECTION. REPAIRED LT/RT FS 559 BULKHEAD WEB AND CAP ANGLE THAT FAILED NDT AT LT/RT CAP ANGLE LBL 18 AND RT WEB AT WL 58.10 IAW REO 601R-53-41-260, REV C. COMPLIED WITH EC/TC REO 601R-53-41-260 IAW REO 601R-53-41-260, REV C.